The generator copied the yaml value into the tag, so false became
"@reboot_required False", and the metadata parsers treat any value as
set. QGC prompted for a reboot after changes to 35 parameters that
apply live, among them the gyro filters, log rotation and ADSB squawk.
Emit flag tags only when true. volatile had the same flaw, though no
parameter sets it false yet.
Assisted-by: Claude:claude-opus-5-5
Signed-off-by: Jacob Dahl <dahl.jakejacob@gmail.com>
(cherry picked from commit 4bf3a5bd51)
- migrate_c_params.py: preserve newlines and paragraph breaks in long
descriptions, use YAML block scalars for multi-line strings
- generate_params.py: support @value tags on float type parameters
(fixes RC*_REV enum values being lost during yaml generation)
Add PWM_*_CENTERx for each servo.
Use a bilinear transform to map actuator_servos to PWM signals.
This solution only works for PWM based servos. Other types of servos are not affected.
* PWM: Add servo trim option
* PWM: Improve documentation of PWM trim feature
* PWM: cleaner clamping and docs typo
* update documentation & safety
* add migration formula
* rename param from trim to center
* docs with center instead of trim
* move clamping and reorder values
* improve documentation
* adress failing range check
* improve documentation
* CA: add event for setting CENTER with TRIM
Signed-off-by: Silvan <silvan@auterion.com>
---------
Signed-off-by: Silvan <silvan@auterion.com>
Co-authored-by: Silvan <silvan@auterion.com>
and remove the possibility to set min > max to reverse.
Initially the idea was to add the checkbox on the UI side, to avoid adding
another param, but I don't think I'll go through the extra effort on the
QGC side.
The implementation assumed timers are defined in the same order as used
in the channels. This could lead to a mismatch between TIMx param and
actual timer config.
Now we use the actual array index, same as in the code.