fix(qmc5883p): scale for the +-2 G range is 15000 LSB/G (#29301)

The driver selects RNG = 11 (+-2 G) and checks it, but scaled the data
by 1/12000, so every field reading was 1.25x too large (measured 1.252x
the world magnetic model), which also triggers the strong magnetic
interference preflight check. The QST datasheet (13-52-19 Rev A) gives
15000 LSB/G for the +-2 G range.

Existing compass calibrations must be redone after this change: the
stored offsets are in the old units.

Assisted-by: Claude:claude-opus-5-5
This commit is contained in:
j3kestrel authored and GitHub committed 2026-10-18 22:08:18 -04:00
1 parent 809e00b439
commit ebf8b69c66
1 file changed
+1 -1
@@ -261,7 +261,7 @@ bool QMC5883P::Configure()
}
}
_px4_mag.set_scale(1.f / 12000.f); // 12000 LSB/Gauss (Field Range = ±2G)
_px4_mag.set_scale(1.f / 15000.f); // 15000 LSB/Gauss (Field Range = ±2G)
_px4_mag.set_range(2.f);
return success;