refactor(timesync): document the Kalman filter prediction

Explain where the process noise terms come from and write the
covariance prediction in Horner form. Shorten the tuning comments.

Assisted-by: Claude:claude-opus-5-5
Signed-off-by: Andrea Bernasconi <andrea.bernasconi@auterion.com>
This commit is contained in:
Andrea Bernasconi committed 2026-11-19 13:51:21 +01:00
1 parent 26cc1b32a3
commit a1fba5c8c5
2 files changed
+13 -21

No files matched your search

+8 -7
View File
@@ -121,8 +121,7 @@ uint64_t Timesync::sync_stamp(uint64_t usec)
void Timesync::add_sample(int64_t offset_us, uint64_t now_us)
{
// Kalman filter with state [offset, skew] in seconds. The skew is a rate [s/s], so the prediction
// stays consistent when the interval between samples changes (e.g. fast initial sync, then 1 Hz).
// Kalman filter with state [offset, skew] in seconds
static constexpr double R = MEASUREMENT_NOISE_STD * MEASUREMENT_NOISE_STD;
const double offset_s = offset_us * 1e-6;
@@ -137,13 +136,15 @@ void Timesync::add_sample(int64_t offset_us, uint64_t now_us)
} else {
const double dt = (now_us - _last_sample_us) * 1e-6;
// Predict
// Predict: x = F x, P = F P F^T + Q in Horner form, with F = [1 dt; 0 1].
// Q adds the skew random walk q over dt
// Q = q * integral_0^dt [s^2, s; s, 1] ds = q [dt^3/3, dt^2/2; dt^2/2, dt].
_time_offset += _time_skew * dt;
_var_offset += dt * (2.0 * _cov_offset_skew + dt * _var_skew) + SKEW_RANDOM_WALK * dt * dt * dt / 3.0;
_cov_offset_skew += dt * _var_skew + SKEW_RANDOM_WALK * dt * dt / 2.0;
_var_skew += SKEW_RANDOM_WALK * dt;
_var_offset += dt * (2.0 * _cov_offset_skew + dt * (_var_skew + dt * SKEW_RANDOM_WALK / 3.0));
_cov_offset_skew += dt * (_var_skew + dt * SKEW_RANDOM_WALK / 2.0);
_var_skew += dt * SKEW_RANDOM_WALK;
// Update
// Update with H = [1 0] (Kalman filter measurement update)
const double innovation = offset_s - _time_offset;
const double k_offset = _var_offset / (_var_offset + R);
const double k_skew = _cov_offset_skew / (_var_offset + R);
+5 -14
View File
@@ -52,20 +52,11 @@ using namespace time_literals;
static constexpr time_t PX4_EPOCH_SECS = 1234567890ULL;
// Kalman filter tuning
//
// The offset and skew are estimated by a two-state Kalman filter (offset, skew) whose
// prediction uses the actual time between samples, so its dynamics are defined in seconds
// and do not depend on how often the caller exchanges timesync packets.
//
// MEASUREMENT_NOISE_STD : Standard deviation of a single observed offset [s], mostly caused
// by asymmetric link delays. Bounded by MAX_RTT_SAMPLE / 2.
//
// SKEW_RANDOM_WALK : Spectral density of the skew random walk [1/s]. Larger values let
// the filter follow skew changes and clock corrections on the remote system faster,
// at the cost of a noisier estimate.
//
// INITIAL_SKEW_STD : Prior uncertainty of the skew [s/s], i.e. the expected crystal tolerance.
// Kalman filter tuning. State: offset [s] and skew [s/s], predicted with the actual time
// between samples, so the response does not depend on the timesync rate.
// MEASUREMENT_NOISE_STD : std of an observed offset [s], mostly asymmetric link delay
// SKEW_RANDOM_WALK : skew random walk density [1/s], higher follows clock corrections faster
// INITIAL_SKEW_STD : prior skew std [s/s], i.e. crystal tolerance
static constexpr double MEASUREMENT_NOISE_STD = 1e-3;
static constexpr double SKEW_RANDOM_WALK = 1e-12;