feat(params): add board-level read-only parameter support (#26522)

Integrators can declare read-only parameters in a per-board YAML file:
readonly_params.yaml.

There are two ways to define the read-only params:
- "block": default writable, explicitly list params to be locked
- "allow": default readonly, explicitly list params to be writable

Enforcement is activated by `param lock` in rcS after all startup
scripts have run, so board defaults and airframe scripts can still set
params during init.

The feedback via MAVLink uses the new
MAV_PARAM_ERROR_READ_ONLY as part of the PARAM_ERROR message.
This commit is contained in:
Julian Oes authored and GitHub committed 2026-04-27 09:06:43 +12:00
1 parent efd05431e8
commit b48ec2dd68
16 files changed
+276 -9

No files matched your search

@@ -226,6 +226,9 @@ MavlinkParametersManager::handle_message(const mavlink_message_t *msg)
PX4_ERR("param types mismatch param: %s", name);
send_error(MAV_PARAM_ERROR_TYPE_MISMATCH, name, -1, msg->sysid, msg->compid);
} else if (param_is_readonly(param)) {
PX4_WARN("param %s is read-only", name);
send_error(MAV_PARAM_ERROR_READ_ONLY, name, -1, msg->sysid, msg->compid);
} else {
// According to the mavlink spec we should always acknowledge a write operation.